Advice / Practical guide Security & Prevention #Dakar#Fire Engineering#Practical guides

Fire Safety in Senegal: Building a Sustainable Compliance Programme

How to structure the fire compliance of an establishment: analysis of classification, evacuation, emergency means, maintenance, training, registers and exercises.

12 March 2024 4 min read
Fire Safety in Senegal: Building a Sustainable Compliance Programme
Vigilus Facilities

At a glance

How to structure the fire compliance of an establishment: analysis of classification, evacuation, emergency means, maintenance, training, registers and exercises.

Fire compliance is not just about buying fire extinguishers. It is based on a coherent approach: identify the framework applicable to the building and the activity, prevent the outbreak, detect quickly, allow evacuation, limit the spread and facilitate emergency intervention.

1. Identify classification and applicable requirements

The level of requirements varies depending on the use of the premises, the number of people accommodated, the height, the products stored and the processes used. The owner, operator and employer must clarify their responsibilities. For a particular establishment or installation at risk, the prescriptions must be confirmed with the competent authorities and professionals.

2. Preventing fire outbreaks

The priority is to reduce ignition sources and the fuel load: electrical installations maintained, hot spot work supervised, compatible storage, technical rooms kept in order, waste evacuated and cooking equipment monitored. Any modification of the activity must be subject to re-evaluation.

3. Guarantee alert and evacuation

Occupants must be able to recognize the alarm and reach a safe area. Clearances, doors, stairs, lighting and signage are kept available. The instructions take into account visitors, isolated workers and people needing assistance.

4. Sizing emergency resources

Fire extinguishers, armed fire taps, detection, alarm, smoke extraction or fixed devices are chosen according to the risks. Their mere presence is not proof of operation: reception, tests, checks and maintenance must be traced.

5. Organize roles and exercises

The people responsible for raising the alert, guiding the evacuation, using first aid and welcoming emergency services must be identified and trained. The exercises check behaviors and the relevance of the plan; each deviation becomes an action followed until closure.

Vigilance on regulatory references

The texts and requirements may change and differ depending on the classification of the establishment. An information article therefore does not replace either a compliance study or the opinion of the competent authorities. The objective is to help the manager to structure his checks and evidence.

The safety file to be kept available

Compliance must be able to be demonstrated by documents consistent with the building, activity and equipment actually present.

  • Plans: Maintain layout, evacuation, cuts, emergency means and access for responders.
  • Records: Trace checks, maintenance, defects, work, exercises and corrective actions.
  • Instructions: Adapt alert, evacuation, assistance, assembly and reception of emergency services.
  • Skills: Identify roles and maintain training of designated individuals.
  • Changes: Reassess the system after work, new use, storage or reorganization of flows.

Pilot indicators

  • updated documents
  • expired checks
  • critical anomalies
  • exercise actions closed

Moving from diagnosis to action

An annual review with operation, maintenance and HSE makes it possible to reconcile obligations, risks and actual status. The precise requirements must be confirmed according to the classification and with the competent authorities.

Distribute responsibilities throughout the building cycle

The designer, the owner, the operator, the employer, the maintenance companies and the occupants intervene at different times. Contractual responsibilities must be consistent with obligations that cannot be delegated. A simple, precise matrix that checks, authorizes, maintains, trains and closes anomalies.

Frame temporary changes

Work, moving, event, exceptional storage or breakdown can neutralize a door, a detector or a power supply. Before the change, the manager assesses the effect on fire scenarios and puts in place compensatory measures: reinforced surveillance, activity limitation, additional means or closure of an area.

Questions for a compliance review

  • Does the classification retained still correspond to usage and numbers?
  • Do the plans correspond to the current premises and equipment?
  • Do all maintenance or inspection reserves have an expiry date?
  • Are the night teams and service providers aware of the instructions?
  • Are people requiring assistance taken into account?

Audit effectiveness, not just presence

A blocked fire door, a hidden fire extinguisher or a faulty control unit physically exist but no longer fulfill their function. The audit checks the availability of barriers and the ability of people to act. The tests and exercises complement the documentary checks.

Treat deviations according to their criticality

An anomaly affecting alert, evacuation or essential protection requires immediate action or formalized compensation. Other deviations are planned, but remain monitored until proven resolved. This hierarchy prevents a voluminous register from hiding some major dangers.